TRU250A1

The TRU is connected to the aircraft three-phase AC network of 115 V AC at a frequency of 400 Hz to supply electrical on-board systems and to load the battery with a DC voltage of 28 V DC. The potential free output voltage is provided over the total range of load and under varying input voltage conditions. The unit is capable to withstand overload for a limited time duration. An integrated fan provides respective ventilation in the specified temperature range.

Technical Data 
Input: 
Nominal AC input voltage3 x 115 / 200 VAC, 400 Hz
Operating AC input voltage3 x 108 .... 118 / 187 .... 205 VDC
Operating AC input frequency400 ± 30 Hz
Current consumption (at 250 Amp, nominal load)approx. 25 Amps at 115/200 VAC
Input power factor> 0.9 lag at nominal load
Output: 
Normal DC output voltage28 VDC
Nominal load250 Amps continuously
Overload375 Amps for 2 minutes
750 Amps for 5 seconds
Efficiency> 0.85 at 115/200 VDC input voltage
Output ripple voltagetypical < 2.5 V p-p maximum
Power consumption without load < 150 VA
MTBF: 
Predicted MTBF> 20 000 operational hours
Mechanical Data: 
Dimensions (length x width x height)229 mm x 177 mm x 154 mm
Mass (weight)max. 9.0 kg
Coolinginternal fan
Pin assignments: 
AC input connector connector type
Amphenol 6020 B-00-E14-04 PN
115 AC Input, Phase APin P1-A
115 AC Input, Phase BPin P1-B
115 AC Input, Phase CPin P1-C
DC Terminal block
28 V pos. DC input Stud M8
28 V neg. DC inputStud M6
Chassis ground via grounding cableshield of coaxial connector
Environmental Conditions: 
Operating temperature -26 °C to +55 °C
Short term operating temperature-26° C to +75 °C
Storage temperature-40 °C to +90 °C
Altitude48 000 ft at 35 °C max
20 000 ft at 55 °C max
Constant accelerationapplicable 10 g
Operational vibrationsapplicable 10 Hz to 2000 Hz
Fungusapplicable
Humidity xxxxCat. A
Waterproofnessapplicable
Salt sprayapplicable
Sand and dustapplicable
Fire resistanceapplicable
Magnetic effectapplicable
EMIDEF STAN 59-41
Conducted emission on power linesapplicable 20 Hz to 150 MHz
Radiated emission E field14 kHz to 18 GHz
H field radiation20 Hz to 50 kHz
Exported transients on power linesDEF STAN 59-41
  
» close window