The static Inverter is connected to the 28 V DC network or the battery to supply electrical on-board systems with an AC voltage of 230 V AC at a selectable frequency of 35, 45, 50 or 60 Hz. The potential free three-phase square-wave voltage is regulated over the total range of load under varying input voltage conditions. The unit is capable to withstand overload and short circuit for a limited time duration. The integrated monitoring circuits verify the input voltage as well as the internal unit temperature to remain inside the acceptable limits and provide this status information to externally connected systems. The inverter is activated via an external release signal.
| Technical Data | |
|---|---|
| Input: | |
| Nominal DC input voltage | 24 VDC |
| Operating DC input voltage | 24 VDC, -30%/+20% |
| Current consumption (at 1000 VA, nominal load) | approx. 47 Amp at 24 VDC |
| Output: | |
| Normal AC output voltage | 230 VAC ± 10 %, Phase to Phase, UA eff |
| Abnormal AC output voltage (16,8 V – 22 V DC in) | >= 200 VAC |
| AC output frequency | 35, 45, 50 or 60 Hz ± 6% selectable |
| Number of phases | 3 phase |
| Nominal load | up to 1000 W, 1200 VA |
| Overload | 2000 VA for 30 seconds 3000 VA for 20 seconds |
| Efficiency | > 0.90 |
| Protection: | |
| Built-in-Test (relay) for overheat and loss of input voltage | open signal in case of failure (Rückmeldesignal) |
| AC generation stop | at overheat (automatic recovery) |
| Release control | by external control of internal release relay (Freigabe) |
| MTBF: | |
| Predicted MTBF | > 50 000 hours |
| Mechanical Data: | |
| Dimensions (length x width x height) | 213.5 mm x 250.5 mm x 79.5 mm |
| Mass (weight) | < 4 kg |
| Cooling | convectional cooling |
| Pin assignments: | |
| Pin assignments: P1 | |
| 28 V pos. DC input | Pin 32 + 8 |
| 28 V neg. DC input | Pin 28 + 4 |
| Release Control + | Pin 22 |
| Release Control - | Pin 24 |
| Built-in Test output signal 1 | Pin 18 |
| Built-in Test output signal 2 | Pin 20 |
| Frequency Selection + | Pin 16 |
| Frequency Selection - | Pin 14 |
| nc | Pin 12 |
| Pin assignments: J1 | |
| 230 VAC output 1 | Pin L1 |
| 230 VAC output 2 | Pin L2 |
| 230 VAC output 3 | Pin L3 |
| Case Ground | Pin L4 |
| Environmental Conditions: | |
| (acc. DIN VDE 0115 (T1) / 12.92) | |
| Storage temperature | -40 °C to +85 °C |
| Operational temperature | -40 °C to +70 °C |
| Altitude | max. 2 000 m (above sea level) |
| Humidity | 0 to 100 % |
| Isolation | VDE 0115, VDE 0169/11.81 |
| EMI | VDE 0871, VDE 0875 |